Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Taiwan J Ophthalmol ; 14(1): 3-14, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38655001

RESUMO

Since the establishment of the first eye bank in the 1940s, their role has evolved to face new challenges. With the recent development of lamellar keratoplasties, eye banks play an even bigger role in the selection and preparation of donor tissues. The increasing number of keratoplasty techniques and the high demand for "ready-to-use" tissues are challenging eye banks to improve and develop new preparation techniques. Besides necessary examinations, new approaches of tissue analysis in eye banks allow a better/optimized selection of corneal tissues. These new challenges in tissue preservation, preparation, and selection are propelling eye banks into a new era of modern eye banking.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38354750

RESUMO

PURPOSE: To evaluate the long-term outcome of intravitreal bevacizumab in eyes with diabetic macular oedema (DME) following a PRN (pro re nata) regimen. Additionally, we investigated the effect of the presence of disorganisation of the retinal inner layers (DRILs) and pachychoroid (PC) at baseline on clinical outcome. METHODS: This retrospective study included 112 naïve eyes with DME that were followed up for 2 years. All eyes were treated with six initial bevacizumab injections at monthly intervals and then received treatment according to a PRN regimen. In case of poor response to bevacizumab, therapy was switched to other agents. Main outcome measures included: best-corrected visual acuity (BCVA), central macular thickness (CMT), and number of intravitreal injections (IVI s). In addition, we examined the effect of the presence of DRILs and PC at baseline on clinical outcome. RESULTS: BVCA improved significantly and CMT decreased significantly during the first 2 years of treatment. The number of IVI s per eye was 11.1 ± 4.8 at the end of the second year. Treatment had to be switched to other agents in 47 eyes (42%). The timing of switching was 12.4 ± 6.1 months after a mean of 9.2 ± 3.3 IVI s. Patients with DRILs at baseline (29.5%) had significantly worse BCVA at all time points before and after treatment, although CMT was significantly lower before treatment and comparable to patients without DRILs during treatment. Patients with PC at baseline (35.7%) had no significant differences in BVCA and CMT at all time points compared with patients without PC. CONCLUSIONS: This study demonstrates statistically significant functional and anatomical improvement in patients with DME treated with intravitreal bevacizumab after 2 years. However, more than 40% of eyes required a switch in therapy. The presence of DRILs at baseline had a negative effect whereas the presence of PC at baseline had no effect on clinical outcome.

3.
Acta Ophthalmol ; 2023 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-38131522

RESUMO

PURPOSE: This study investigated the influence of cleanroom conditions on the discard rates of donor corneas in a German university eye bank. METHODS: Discard rates were analysed from 2017 to 2020 at the LIONS Cornea Bank at Saarland University Medical Center. 1941 corneas from 971 donors were included. 1262 corneas (65.1%) were stored in a class D cleanroom from 2017 to 2019 and processed in a cleanroom class A sterile bank (group 1). 679 corneas (34.9%) were continuously stored in a class B cleanroom and processed in a class A cleanroom safety cabinet in the same room from 2019 to 2020 (group 2). The target parameter of this work was the number of contamination-related discards. Although they cannot be influenced by the spatial conditions, the discards due to insufficient endothelial quality, serology, contraindications, scars and technical causes were also recorded. Statistical analysis was performed using SPSS and various testing procedures. RESULTS: In group 1, significantly more corneas were discarded due to positive serology (6.9%|3.8%, p = 0.020). There was no significant change between both groups for either contamination or the other reasons for discard. CONCLUSION: Optimization of hygiene standards from cleanroom class D to B did not reduce contamination. Serology, endothelial quality, medical contraindications and the presence of scars cannot be influenced by cleanroom conditions.

4.
Artigo em Inglês | MEDLINE | ID: mdl-37673087

RESUMO

BACKGROUND: This study aimed to assess the vision-related quality of life (VRQol) of patients with age-related macular degeneration (AMD) and to evaluate VRQol according to different types of AMD. METHODS: In this small-scale, single-center, prospective investigation, patients with AMD and subjects without any signs of macular disease were asked to complete the NEI-VFQ-39. A total of 159 subjects were included and grouped according to the type of AMD as follows: 40 patients with dry AMD in both eyes (DD), 40 patients with exudative AMD in one eye (DE), 41 patients with exudative AMD in both eyes (EE), and 38 subjects without any signs of macular disease, as a control group (CG). RESULTS: The average age of the participants was 76 ± 7 years, and 44% were male. Most participants were retired (22.4%), and 75% of patients were initially diagnosed by their ophthalmologist. All the AMD groups had significantly worse overall VRQol than the CG. For general vision, near vision, mental health, and role difficulties, all the AMD groups had significantly lower scores than the CG. For distance vision, color vision, peripheral vision, driving difficulties, dependency, and social functioning, only patients in the EE and DE groups had significantly worse scores than the CG. The type of retinal fluid in patients with exudative AMD had no effect on overall VRQol; however, we found that the presence of pigment epithelial detachment could be associated with more role difficulties, such as completing work or working long hours. CONCLUSION: All types of AMD had a negative effect on vision-related quality of life. This effect was significantly more pronounced in patients with exudative AMD in at least one eye. However, the type of retinal fluid in patients with exudative AMD had no influence on their overall vision-related quality of life.

5.
BMJ Open Ophthalmol ; 8(Suppl 2): A10, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37604529

RESUMO

PURPOSE: With the increasing demand for corneas, eye banks must optimize and extend their sources of tissue donation. On the other hand, corneal transplantation is a specialized procedure performed in hospitals with high quality standards and ideally an integrated eye bank. In this report we would like to focus on an international win-win-win agreement between the Department of Ophthalmology at Saarland University Medical Center (Homburg/Saar, Germany), the LIONS Eye Bank Saar-Lor-Lux, Trier/Westpfalz and the four major non-university hospitals without corneal transplantation competence in Luxembourg. METHODS: In 2012, at the initiative of the Luxembourgish Ministry of Health and Department of Ophthalmology (Homburg/Saar, Germany), an international agreement was established with the Centre Hospitalier du Luxembourg (Luxembourg). Administrative and legislative rules were developed. Luxembourgish nursing personnel attended a practical training program for corneal excision at the Department of Ophthalmology in Homburg/Saar allowing them to harvest the two first corneal donors on site by themselves during the first year. In the following years two more hospitals, the Centre Hospitalier Emile Mayrisch (Esch-sur-Alzette, Luxembourg) and the Hôpitaux Robert Schuman (Kirchberg, Luxembourg), joined the cooperation. RESULTS: From 2012 until 2021, three hospitals in Luxembourg donated 779 corneas to the LIONS Eye Bank of the Saarland University Medical Center in Homburg/Saar (Germany). In return, 308 Luxembourgish patients have received a corneal transplantation at the Department of Ophthalmology in Homburg/Saar. In 2022, the extension continued and an agreement with a fourth hospital in Luxembourg at the Centre Hospitalier du Nord (Ettelbruck, Luxembourg) was signed providing even more donations. CONCLUSION: The cross-border collaboration for corneal donation and patient treatment has proven to be successful with both numbers of harvested donors and transplanted patients rising. However, international legislation for tissue donation needs to be accurately respected and a quality management system established to provide continuous quality of the donor tissue.


Assuntos
Transplante de Córnea , Bancos de Olhos , Humanos , Luxemburgo , Piridinolcarbamato , Córnea/cirurgia
6.
JAMA Netw Open ; 6(6): e2318025, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-37310742

RESUMO

This cross-sectional study assesses factors associated with SARS-CoV-2 infection rates at the 122nd Annual Congress of the German Society of Ophthalmology in 2022, which was held in-person for the first time in 3 years, during the Omicron wave.


Assuntos
COVID-19 , Humanos , SARS-CoV-2
8.
Front Pharmacol ; 13: 860784, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35721125

RESUMO

Purpose: To assess the morphological and functional outcomes within the first year of treatment with intravitreal brolucizumab for refractory neovascular age-related macular degeneration (nAMD). Methods: This retrospective study included 21 eyes from 19 patients with refractory nAMD followed for 12 months. All patients were switched to brolucizumab after treatment with at least two other anti-vascular endothelial growth factors (VEGF). All eyes received 3x brolucizumab 6 mg/0.05 ml intravitreal injections (IVI) monthly as an upload phase. Then eyes received an IVI every 8 weeks with interval adjustment to every 12 weeks if disease activity was not present. Main outcome measures: best corrected visual acuity (BCVA), central macular thickness (CMT) and retinal fluid distribution. In addition, we reported the adverse event rate. Results: The number of previous anti-VEGF IVIs/eye was 36 ± 22 before switching to brolucizumab. BCVA (ETDRS) was 51 ± 16 before treatment and 50 ± 19 at week 52 (p = 0.6). CMT was 374 ± 158 µm before treatment and 298 ± 92 µm at week 52 (p = 0.01). The number of IVIs/eye decreased from 9.6 ± 1.9 IVIs in the last year before switching to 6.4 ± 0.9 IVIs in the first year after switching to brolucizumab (p < 0.001). The rate of eyes with subretinal fluid and pigment epithelial detachment decreased at week 52. Finally, two cases of intraocular inflammation were observed as adverse events. Conclusion: In the first year of treatment, intravitreal brolucizumab was able to stabilize visual acuity with significantly less IVIs in patients with refractory nAMD. It also improved anatomic outcomes in these patients, particularly reducing subretinal fluid and pigment epithelial detachment and subsequently central macular thickness. However, two cases of intraocular inflammation were observed as adverse events.

9.
BMC Ophthalmol ; 22(1): 17, 2022 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-35012494

RESUMO

BACKGROUND: With the increasing demand for corneas, eye banks must optimize the tissue donation, collection, and selection process. This retrospective monocentric study analyzed the approval rates for corneal donation and the origin of and reasons for discarding donor corneas from 2010 to 2019. METHODS: Data included the number of deceased, approval or rejection by the family for corneal donation and contraindications. Corneal grafts were included from all deceased persons who were full-body and multi-organ donors at the Saarland University Medical Center (UKS) and from external institutions. Additional analyzed parameters included endothelial cell count (ECC), blood sample serology for infections, and conjunctival swab testing . RESULTS: A total of 1748 corneoscleral buttons were harvested from 10,265 deceased persons (17% with no contraindication) at the UKS between 2010 and 2019, with a consent rate of 23.3%. The number of keratoplasties increased from 136 in 2010 (15% of the deceased, total = 925) to 251 in 2019 (21%, total = 1214). Both the general and department-specific data showed similar percentages for corneal donation over the years, with intensive care and palliative units recently providing the most corneas. The increase in the number of corneas processed by the cornea bank over the years (368 in 2010 compared with 857 in 2019) was linked both to a better internal supply in 2010 (262, 71.2% of the total) compared with 2019 (519, 60.6%) and to an external supply by reinforcement of cooperation with external hospitals, including Luxembourg in 2010 (106, 28.8% of the total) compared with 2019 (338, 39.4%). A total of 195 of 377 corneas (52%) were discarded in 2009 compared with 260 out of 715 (36%) in 2019. The main reasons for discarding were low ECC (36% of discarded corneas in 2009; 11% in 2019), positive conjunctival swab (11% in 2009; 13% in 2019), and blood sample serology (6% in 2009 and in 2019). CONCLUSION: Despite an increasing number of donors, the demand for corneas is still rising. Improved cooperation with internal departments and with external clinics has led to an increasing number of explanted corneas. The main reason for discarding corneas was low ECC, followed by a positive conjunctival swab for fungal or bacterial contamination and serology. Increased donation rates and continued improvements in collection and selection processes are necessary to cover the high demand for corneas.


Assuntos
Transplante de Córnea , Bancos de Olhos , Córnea , Humanos , Estudos Retrospectivos , Centros de Atenção Terciária , Doadores de Tecidos , Universidades
11.
BMJ Open Ophthalmol ; 7(Suppl 2): A7, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-37282706

RESUMO

PURPOSE: To evaluate the reliability and efficiency of sterile corneal thickness measurements of donor corneas stored in a plastic culture flask filled with organ culture medium I (MI) or II (MII) based on tomographic data using two different software: the built-in software of the anterior segment OCT (AS-OCT) and a MATLAB self-programmed software. METHODS: Twenty-five (25) donor corneas (50%) stored in MI and 25 (50%) in MII were imaged 5 times consecutively using an AS-OCT. The central corneal thickness (CCT) was measured both with the manual measurement tool of the AS-OCT (=CCTm) and with a MATLAB self-programmed software allowing (semi-)automated analysis (=CCTa). We analyzed the reliability of CCTm and CCTa using Cronbach´s alpha (α) and Wilcoxon signed-rank test. RESULTS: Concerning CCTm, 68 measurements (54.4%) in MI and 46 (36.8%) in MII presented distortions in the imaged 3D-volumes and were discarded. Concerning CCTa, 5 (4%) in MI and 1 (0.8%) in MII were not analyzable. The mean (± SD) CCTm was 1129 ± 6.8 in MI and 820 ± 5.1 µm in MII. The mean CCTa was 1149 ± 2.7 and 811 ± 2.4 µm, respectively. Both methods showed a high reliability with a Cronbach´s α for CCTm of 1.0 (MI/MII) and for CCTa of 0.99 (MI) and 1.0 (MII). Nevertheless, the mean SD of the 5 measurements was significantly higher for CCTm compared to CCTa in MI (p = 0.03), but not in MII (p = 0.92). CONCLUSIONS: Sterile donor tomography proves to be highly reliable for assessment of CCT with both methods. However, due to frequent distortions regarding the manual method, the (semi-)automated method seems to be more efficient and should be preferred.


Assuntos
Bancos de Olhos , Infertilidade , Humanos , Paquimetria Corneana/métodos , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica/métodos , Córnea/diagnóstico por imagem
12.
Cell Tissue Bank ; 23(4): 695-706, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34773544

RESUMO

To evaluate the reliability and efficiency of sterile pachymetric measurements of donor corneas based on tomographic data using two different methods: a "manual" and a "(semi-)automated" method. Twenty-five (25) donor corneas (50%) stored in MI and 25 (50%) in MII were imaged 5 times consecutively using an anterior segment OCT (AS-OCT). The central corneal thickness (CCT) was measured both with the manual measurement tool of the AS-OCT (= CCTm) and with a MATLAB self-programmed software allowing (semi-)automated analysis (= CCTa). We analyzed the reliability of CCTm and CCTa using Cronbach´s alpha (α) and Wilcoxon signed-Rank Test. Concerning CCTm, 68 measurements (54.4%) in MI and 46 (36.8%) in MII presented distortions in the imaged 3D-volumes and were discarded. Concerning CCTa, 5 (4%) in MI and 1 (0.8%) in MII were not analyzable. The mean (± SD) CCTm was 1129 ± 6.8 in MI and 820 ± 5.1 µm in MII. The mean CCTa was 1149 ± 2.7 and 811 ± 2.4 µm, respectively. Both methods showed a high reliability with a Cronbach´s α for CCTm of 1.0 (MI/MII) and for CCTa of 0.99 (MI) and 1.0 (MII). Nevertheless, the mean SD of the 5 measurements was significantly higher for CCTm compared to CCTa in MI (p = 0.03), but not in MII (p = 0.92). Sterile donor tomography proves to be highly reliable for assessment of CCT with both methods. However, due to frequent distortions regarding the manual method, the (semi-)automated method is more efficient and should be preferred.


Assuntos
Bancos de Olhos , Tomografia de Coerência Óptica , Paquimetria Corneana , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica/métodos , Córnea/diagnóstico por imagem
14.
Int J Retina Vitreous ; 7(1): 74, 2021 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-34876232

RESUMO

BACKGROUND: To assess the morphological and functional outcome of intravitreal aflibercept following the treat and extend protocol compared to the fixed protocol for treatment of eyes with neovascular age-related macular degeneration. METHODS: This retrospective study included 126 eyes of 113 patients with primary onset neovascular age-related macular degeneration who were followed for 12 months. All eyes were treated with 2 mg/0.05 mL aflibercept. All eyes received an upload with three monthly aflibercept injections. We subsequently studied two groups of eyes. For group 1, 54 eyes were treated following the treat and extend protocol. For group 2, 72 eyes were treated following the fixed protocol (fixed 2-monthly interval). Main outcome measures included: best corrected visual acuity (BCVA), central macular thickness (CMT) and number of injections. RESULTS: BCVA (logMAR) in group 1 vs group 2 was (0.61 ± 0.3 vs 0.72 ± 0.3, p = 0.09) before treatment and (0.48 ± 0.3 vs 0.51 ± 0.3, p = 0.6) after one year of treatment. CMT in group 1 vs group 2 was (371 ± 101 µm vs 393 ± 116 µm, p = 0.5) before treatment and (284 ± 60 µm vs 290 ± 67 µm, p = 0.1) after one year of treatment. Number of injections/eye in group 1 vs group 2 was (8.5 ± 2.2 vs 7.0 ± 0, p < 0.001). CONCLUSIONS: Significant differences regarding BCVA and central macular thickness were not found between both treatment protocols during the first year of treatment using aflibercept. However, a significantly higher number of injections was needed for eyes in the treat and extend group during the first year of treatment. This might suggest that aflibercept should better not be extended past an 8 weeks interval during the first year of treatment. STUDY REGISTRATION: This study was approved by the Ethics Committee of the Medical Association of Saarland, Germany (Nr. 123/20, Date: 16.06.2020). All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards. This article does not contain any studies with animals performed by any of the authors.

16.
Ophthalmologe ; 118(1): 53-55, 2021 Jan.
Artigo em Alemão | MEDLINE | ID: mdl-32211921

RESUMO

A Wessely immune ring can be found in various corneal infections as well as in non-infectious processes. Its appearance can aid in the differential diagnosis but can also be misleading. A definitive diagnosis can only be reached when all clinical and microbiological findings are taken into consideration. This article discusses and critically reflects on the differential diagnostic considerations and treatment strategies in the context of a case report on a 31-year-old patient with contact lenses and diffuse endothelial decompensation with a focal, mid-peripheral infiltrate and a Wessely immune ring.


Assuntos
Ceratite por Acanthamoeba , Lentes de Contato , Ceratite , Ceratite por Acanthamoeba/diagnóstico , Adulto , Diagnóstico Diferencial , Humanos , Ceratite/diagnóstico , Ceratite/terapia
17.
Cornea ; 40(6): 733-740, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-33290320

RESUMO

PURPOSE: To determine the changes of corneal thickness and curvature of human corneal grafts in organ culture medium II, containing dextran T500 6%, before keratoplasty. METHODS: We examined the tomography of 24 corneas from our eye bank transferred from medium I into medium II. Images were repeated hourly during 24 hours using an anterior segment optical coherence tomography. The central corneal thickness (CCT) was measured with the manual measurement tool of the anterior segment optical coherence tomography. The radii of curvature (anterior flat and steep and posterior flat and steep) were measured with a MATLAB self-programmed software for "sterile donor tomography." RESULTS: The mean CCT (±SD) at baseline (T0) was 727 ± 156 µm. It reached 581 ± 103, 506 ± 84, 472 ± 79, and 456±7 µm after 6, 12, 18, and 24 hours, respectively. After 12 hours, 83% of the final deswelling was achieved. The radii of curvature (±SD) at baseline (T0) were (posterior flat, posterior steep, anterior flat, and anterior steep) 6.6 ± 0.5, 6.2 ± 0.5, 7.7 ± 0.4, and 7.4 ± 0.4 mm, respectively. After 24 hours, the radii of curvature reached 6.8 ± 0.1, 6.6 ± 0.3, 7.6 ± 0.1, and 7.4 ± 0.2 mm, respectively. CONCLUSIONS: The kinetics of the deswelling process in medium II follow a hyperbolic curve. Considering a CCT of 506 µm at T12, we assume that a time interval of 12 hours in medium II might be enough for clinical purposes. This result might help to keep storage in medium II as short as possible to escape potential toxic effects of dextran in medium II. The radius of curvature does not seem to change within 24 hours for all measured surfaces.


Assuntos
Córnea/patologia , Edema da Córnea/fisiopatologia , Dextranos/uso terapêutico , Ceratoplastia Penetrante , Substitutos do Plasma/uso terapêutico , Córnea/efeitos dos fármacos , Edema da Córnea/diagnóstico por imagem , Meios de Cultura , Feminino , Humanos , Masculino , Técnicas de Cultura de Órgãos , Soluções para Preservação de Órgãos , Tamanho do Órgão , Fatores de Tempo , Doadores de Tecidos , Tomografia de Coerência Óptica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...